| Institution |
Generic Type |
Specific Type |
Manufacturer/Model |
Technical Specification |
Type of measurements |
Staff contact |
Phone |
e-mail |
| Dundee |
Biomolecular Mass Spectrometer |
Proteomics Analyser, MALDI based |
Applied Biosytems 4700 |
|
MS analysis of wide range of biomolecules, e.g., proteins, peptides, small molecules |
Douglas Lamont |
01382 388275 |
d.j.lamont@dundee.ac.uk |
| Dundee |
Biomolecular Mass Spectrometer |
Voyager, MALDI based |
Applied Biosytems DE-STR |
|
MS analysis of wide range of biomolecules, e.g., proteins, peptides, small molecules |
Douglas Lamont |
01382 388275 |
d.j.lamont@dundee.ac.uk |
| Dundee |
Mass Spectrometer |
Mass Spectrometer, Electrospray based |
Waters Q-TOF II |
|
MS/MSMS analysis of wide range of biomolecules/ compounds, e.g., proteins, peptides, small molecules |
Douglas Lamont |
01382 388275 |
d.j.lamont@dundee.ac.uk |
| Dundee |
Mass Spectrometer |
Mass Spectrometer, Electrospray based |
Waters Quattro Ultima |
|
MS/MSMS analysis of wide range of biomolecules/ compounds, e.g., proteins, peptides, small molecules |
Douglas Lamont |
01382 388275 |
d.j.lamont@dundee.ac.uk |
| Dundee |
Mass Spectrometer |
Mass Spectrometer, Electrospray based |
Applied Biosytems Mariner |
|
MS/MSMS analysis of wide range of biomolecules/ compounds, e.g., proteins, peptides, small molecules |
Douglas Lamont |
01382 388275 |
d.j.lamont@dundee.ac.uk |
| Edinburgh |
Mass Spectrometer |
Q-ICP-MS |
Thermo VG VG PlasmaQuad 3 |
Solution |
ICP metals & isotopes, ppb-ppq |
Dr L Eades |
0131 650 4757 |
Lorna.Eades@ed.ac.uk |
| Edinburgh |
Mass Spectrometer |
|
Bruker 3.0 T FT-MS |
|
|
Dr P Barran |
0131 650 7533 |
perdita.barran@ed.ac.uk |
| Edinburgh |
Mass Spectrometer |
|
Bruker 9.4 T FT-MS |
|
|
Dr P Barran |
0131 650 7533 |
perdita.barran@ed.ac.uk |
| Edinburgh |
Mass Spectrometer |
GC-MS |
|
|
|
Dr P Barran |
0131 650 7533 |
perdita.barran@ed.ac.uk |
| Edinburgh |
Mass Spectrometer |
|
Applied Systems MALDI-Tof |
|
|
Dr P Barran |
0131 650 7533 |
perdita.barran@ed.ac.uk |
| Edinburgh |
Mass Spectrometer |
|
Kratos MS50 |
|
|
Dr P Barran |
0131 650 7533 |
perdita.barran@ed.ac.uk |
| Edinburgh |
Mass Spectrometer |
|
Kratos Profile |
|
|
Dr P Barran |
0131 650 7533 |
perdita.barran@ed.ac.uk |
| Edinburgh |
Mass Spectrometer |
|
Q-Tof |
|
|
Dr P Barran |
0131 650 7533 |
perdita.barran@ed.ac.uk |
| Edinburgh |
Mass Spectrometer |
|
Finnegan 4500 |
|
|
Dr P Barran |
0131 650 7533 |
perdita.barran@ed.ac.uk |
| Edinburgh |
Mass Spectrometer |
LCQ-MS |
|
|
|
Dr P Barran |
0131 650 7533 |
perdita.barran@ed.ac.uk |
| Glasgow |
Mass Spectrometer |
Benchtop GC/MS |
Hewlett Packard 5890/5971 Series II |
EI Mode GC/MS |
Low resolution EI GC/MS |
J Tweedie |
0141 330 6585 |
jamest@chem.gla.ac.uk |
| Heriot-Watt |
Mass Spectrometer |
|
Kratos Concept 1S |
Double Sector, High Res., EI mode |
Low Res and High Res Electron Impact Mass Spectrometry |
Gerry Smith |
0131 451 8024 |
G.P.Smith@hw.ac.uk |
| Heriot-Watt |
Mass Spectrometer |
|
Thermoquest (Finigan) Benchtop MS |
Single Quad, ESI mode |
Low Res Electrospray Mass Spectrometry |
Gerry Smith |
0131 451 8024 |
G.P.Smith@hw.ac.uk |
| St Andrews |
Mass Spectrometer |
LC, ESI Mass Spectrometer |
Micromass LCT |
Relectron |
Whole protein, small molecule |
Dr C Botting |
01334 467186 |
cb2@st-andrews.ac.uk |
| St Andrews |
Mass Spectrometer |
ESI/MALDI-MS/MS Mass Spectrometer |
Applied Systems Q-Star Pulsar X |
LC & static nanoflow |
Tryptic digest |
Dr C Botting |
01334 467186 |
cb2@st-andrews.ac.uk |
| St Andrews |
Mass Spectrometer |
MALDI -TOF Mass Spectrometer |
Micromass TofSpec 2E |
linear & reflectron |
Tryptic digest & whole protein |
Dr C Botting |
01334 467186 |
cb2@st-andrews.ac.uk |
| St Andrews |
Mass Spectrometer |
|
Micromass GCT |
|
|
C Horsburgh |
01334 463790 |
cerh@st-andrews.ac.uk |
| St Andrews |
Mass Spectrometer |
|
Micromass LCT |
|
|
C Horsburgh |
01334 463790 |
cerh@st-andrews.ac.uk |
| St Andrews |
Mass Spectrometer |
ICP-MS Spectrometer |
Agilent 7500 |
Solution, solid plus laser |
ICP |
S Williamson |
01334 463697 |
sw14@st-andrews.ac.uk |
| Strathclyde |
Mass Spectrometer |
GCMS |
Thermofinnigan Polaris Q GC/MS |
Ionisation types: EI/CI |
Low resolution EI/CI GC/MS for small molecules. Mass range 50-650m/z. |
Ms Pat Keating |
0141 548 4720 |
p.e.keating@strath.ac.uk |
| Strathclyde |
Mass Spectrometer |
|
Thermofinnigan LCQ DUO |
Ionisation types: ESI |
Low Res Electrospray Mass Spectrometry small molecules, biomolecules (multiple and singly charged) etc. Mass range 50-200m/z. |
Ms Pat Keating |
0141 548 4720 |
p.e.keating@strath.ac.uk |
| Strathclyde |
Mass Spectrometer |
ICPMS |
PE ELAN 6000 |
|
Multi-element trace analysis |
Dr C M Davidson |
0141 548 4212 |
c.m.davidson@strath.ac.uk |
| Strathclyde |
Mass Spectrometer |
GCMS |
PE TurboMass |
With single-shot TD unit |
|
Dr L T Gibson |
0141 548 4212 |
lorraine.gibson@strath.ac.uk |